DNC and CNC setting for Pro Elesta
These settings for DNC Precision software only. It may not work with other software.
Set the following parameters on the machine
| P68 | 3 |
| P69 | 0 (ISO code, 7 data bits, Even parity, 2 stop bits) |
| 39 (baud rate) | 4800 |
| 44 (punch device) | 0 |
| 46 (output device) | 0 |
| 54 (read device) | 1 |
| 57 (time before alarm) | 90 |
| Optional parameter bits #1 (ISO code) | 0000 1011 |
| Optional parameter bits #2 | 0000 0000 |
| Optional parameter bits #12 (stop bits, parity) | 1010 0010 |
| Optional parameter bits #21 | 0000 0000 |
|
Set the following parameters on the PC
Serial port tab
| Machine name | Pro Elesta |
| Serial port | COM2 (or any free COM port) |
| Baud | 1200 |
| Data bits | 7 |
| Parity | Even |
| Stop bits | 2 |
Data flow control tab
| Use DTR | False |
| Use RTS | True |
| Require DSR | False |
| Require CTS | True |
| Set RTS | False |
| Set DTR | False |
| Software flowcontrol | None |
| Xon char | #11 |
| Xoff char | #13 |
Data exchange format tab
| Format mode | Uniform |
| Format parameters | Program start: %
Program end: %
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No |
| Null modem cable, without handshake |
| PC, 9pin, DB9M |
CNC, 25pin, DB25 |
|
|
|
| Null modem cable, with full handshake |
| PC, 9pin, DB9M |
CNC, 25pin, DB25 |
|
|
|
| Null modem cable, without handshake |
| PC, 25pin, DB25M |
CNC, 25pin, DB25 |
|
|
|
| Null modem cable, with full handshake |
| PC, 9pin, DB25M |
CNC, 25pin, DB25 |
|
|
|
If you have successfully connected DNC Precision
with any other controller not in this list, we would appreciate
your sending us the
details to add to the list.
Note: We are not
responsible and do not provide guarantee for any of these
settings, that have been sent us by our customers.