DNC and CNC setting for Fagor 8040/8050
These settings for DNC Precision software only. It may not work with other software.
Set the following parameters on the machine
| P0 (baud rate) | 7 (9600) |
| P1 (data bits) | 1 (8 data bits) |
| P2 (parity) | 0 (no parity) |
| P3 (stop bits) | 0 (one stop bit) |
| P4 (protocol type) | 0 (general device) |
| P5 (Fagor DNC is active) | No |
| P6 (Debug) | No |
| P7 (Abort characters) | 0 |
| P8 (EOL characters) | 0 (LF) |
| P9 (EOT characters) | 0 |
| P10 (Xon and Xoff) | Yes |
If you want you can change baud rate in the parameter P0 to:
| Baud | Parameter value |
| 1200 | 4 |
| 2400 | 5 |
| 4800 | 6 |
| 9600 | 7 |
| 19200 | 8 |
| 38400 | 9 |
| 57600 | 10 |
|
|
Set the following parameters on the PC
Serial port tab
| Machine name | Fagor 8040/8050 |
| Serial port | COM2 (or any free COM port) |
| Baud | 9600 |
| Data bits | 8 |
| Parity | None |
| Stop bits | 1 |
Data flow control tab
| Use DTR | False |
| Use RTS | False |
| Require DSR | False |
| Require CTS | False |
| Set RTS | False |
| Set DTR | False |
| Software flowcontrol | Both |
| Xon char | #11 |
| Xoff char | #13 |
Data exchange format tab
| Format mode | Uniform |
| Format parameters | Program start:
Program end:
Line start:
Line end: #0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No |
| Null modem cable, without handshake |
| PC, 9pin, DB9M |
CNC, 25pin, DB25 |
|
|
| Null modem cable, without handshake |
| PC, 25pin, DB25M |
CNC, 25pin, DB25 |
|
|
If you have successfully connected DNC Precision
with any other controller not in this list, we would appreciate
your sending us the
details to add to the list.
Note: We are not
responsible and do not provide guarantee for any of these
settings, that have been sent us by our customers.