DNC and CNC setting for Bosch alpha 3
These settings for DNC Precision software only. It may not work with other software.
Set the following parameters on the machine
You need to set the baud rate = 1200
| Select edit parameters mode [MODE] [N+1] |
| Output current the 'Baud' parameter value [A+1] [A+1] |
| Clear current value |
| Set parameter value = 7 |
| Save changes |
|
The baud rate can be:
| 50 bps | 0 |
| 75 bps | 1 |
| 110 bps | 2 |
| 134.5 bps | 3 |
| 150 bps | 4 |
| 200 bps | 5 |
| 600 bps | 6 |
| 1200 bps | 7 |
| 1800 bps | 8 |
| 2000 bps | 9 |
| 2400 bps | 10 |
| 3600 bps | 11 |
| 4800 bps | 12 |
| 7200 bps | 13 |
| 9600 bps | 14 |
|
|
Set the following parameters on the PC
Serial port tab
| Machine name | Bosch alpha 3 |
| Serial port | COM2 (or any free COM port) |
| Baud | 1200 |
| Data bits | 7 |
| Parity | Even |
| Stop bits | 2 |
Data flow control tab
| Use DTR | False |
| Use RTS | True |
| Require DSR | False |
| Require CTS | True |
| Set RTS | False |
| Set DTR | False |
| Software flowcontrol | None |
| Xon char | #11 |
| Xoff char | #13 |
Data exchange format tab
| Format mode | Uniform |
| Format parameters | Program start:
Program end:
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No |
| Null modem cable, without handshake |
| PC, 9pin, DB9M |
CNC, 25pin, DB25 |
|
|
| Null modem cable, with full handshake |
| PC, 9pin, DB9M |
CNC, 25pin, DB25 |
|
|
| Null modem cable, without handshake |
| PC, 25pin, DB25M |
CNC, 25pin, DB25 |
|
|
| Null modem cable, with full handshake |
| PC, 9pin, DB25M |
CNC, 25pin, DB25 |
|
|
If you have successfully connected DNC Precision
with any other controller not in this list, we would appreciate
your sending us the
details to add to the list.
Note: We are not
responsible and do not provide guarantee for any of these
settings, that have been sent us by our customers.